Max. welding current | 500 A |
Welding current at 100% duty cycle | 450 A (focusing gas VARGION S) |
Shielding gas | Ar |
Focusing gases VARIGON S MISON Ar VARIGON He50S MISON He50 |
Ar + 300 ppm O2 Ar + 300 ppm NO Ar / He 50 / 50 + 300 ppm O2 Ar / He 50 / 50 + 300 ppm NO |
Ignition | High-frequency ignition |
Torch cooling | Cooling agent KJELLFROST |
Clamping diameter | 41 mm |
Weight without hose parcel |
700 g |
Power source | PP 500 DC |
Welding current | 5 - 550 A DC |
Welding voltage | 10.2 - 32 V |
Pulsed operation | 0.025 Hz - 15 kHz |
Ambient temperature | -20 °C to 40 °C |
Welding current at 25 °C (surroundings) at 60 % duty cycle at 80 % duty cycle at 100 % duty cycle |
550 A 520 A 450 A |
Welding current at 40 °C (surroundings) at 60 % duty cycle at 80 % duty cycle at 100 % duty cycle |
550 A - 420 A |
Open circuit voltage | 79 V |
Mains (tolerance) | 3x 400 V + N + PE (-25 % to +20 %) |
Frequency | 50 / 60 Hz |
Fuse (slow) | 3 x 35 A |
Maximum connecting power | 22.2 kVA |
Recommended generator output | 39.4 kVA |
cos phi | 0.99 |
Insulation class | H |
Protection class | IP 23 |
Dimensions (L x W x H) | 650 x 550 x 630 mm |
Weight | 78.5 kg |